KSO-G02-2BA-30 KSO-G02-2BD-10 KSO-G02-2BP-30 KSO-G02-4CD-30 Solenoid Valve
Wuhan Xinlaifu Hydraulic Equipment Co., Ltd. is one of the leading manufacturers and suppliers of kso-g02-2ba-30 kso-g02-2bd-10 kso-g02-2bp-30 kso-g02-4cd-30 solenoid valve in China. With abundant experience, we warmly welcome you to buy high quality customized products at competitive price from our factory. Also, OEM&ODM service is available.
Specifications

| Item | Content |
|---|---|
| Type | KSO-G02 Series Hydraulic Solenoid Operated Directional Valve |
| Brand | XLF Hydraulic(OEM) |
| Size / Displacement Range | Size 02, Nominal diameter 1/4 inch (KSO-G02-2BA-30 / KSO-G02-2BD-10 / KSO-G02-2BP-30 / KSO-G02-4CD-30) |
| Rated Working Pressure | 250 bar (25 MPa, continuous working) |
| Peak Pressure | 350 bar (35 MPa, intermittent peak) |
| Mount Flange | Gasket mounting subplate, ISO standard 1/4" valve mounting pattern |
| Port Size | 1/4 inch (G1/4) gasket mounting port |
| Control / Built-in Parts | Solenoid directional control; 2-position / 3-position spool options (2BA/2BD/2BP/4CD); plug-in solenoid coil, DIN connector with indicator lamp, IP65 protection, built-in surge killer optional |
| Recommended Oil | ISO VG32 / VG46 anti-wear mineral hydraulic oil (HLP); operating temperature: -20 ~ +80℃; fluid cleanliness ≥ 20/18/15 ISO 4406 |
Product Overview
If you are designing or maintaining an industrial hydraulic system, the directional control valve is the component that decides where the oil goes. A pump generates flow. A cylinder or motor converts that flow into work. But the valve is what tells the system which actuator to drive, in which direction, at what moment.
The KSO-G02 Series is a solenoid-operated pilot directional control valve - a direct-operated, spring-return (or spring-centered) valve that controls the direction of hydraulic flow in response to an electrical signal. It is compliant with ISO 4401-AB-03 (CETOP 3 / NG6 / NFPA D03) mounting standards, meaning it will bolt directly onto any manifold or subplate machined to the international CETOP 3 interface.
What makes the KSO-G02 different from a standard solenoid valve?
The KSO-G02 is engineered for high-pressure, large-flow operation in a compact package. It achieves a maximum operating pressure of 35 MPa (350 kgf/cm² / 5,076 PSI) and a maximum flow rate of 100 L/min - performance that typically requires a larger physical valve body. For machine tool builders and hydraulic power unit designers, this means you can use a CETOP 3 footprint for applications that would otherwise require a CETOP 5 valve, saving manifold space and reducing system cost.
Which KSO-G02 model do you need? That depends on four questions:
What flow does your system require? → ≤100 L/min confirms G02 (not G03)
What should the valve do when power is removed? → determines spool function (2BA / 2BD / 2BP / 4CD)
What voltage is available? → determines coil code (AC220V / DC24V / AC100V)
What mounting pattern does your manifold use? → CETOP 3 / NG6 / NFPA D03
Core Advantages
2.1 Spool Function Selection – The Most Important Decision
The KSO-G02 offers a wide range of spool configurations. Choosing the wrong one means the valve will not behave as your system requires when the power is removed. Here is a practical selection guide:
| Model | Positions | Spool Function | What Happens When Power is Off | Best For |
|---|---|---|---|---|
| 2BA | 2 | All ports closed | Cylinder stays locked (oil trapped on both sides) | Clamping circuits, holding loads - cylinder must not drift |
| 2BD | 2 | Spring offset, P→A / B→T (or equivalent) | Cylinder returns to home position | Single-acting cylinders, spring-return actuators |
| 2BP | 2 | Spring offset, P→B / A→T (or equivalent) | Cylinder returns in opposite direction | Directional control where default direction is defined |
| 4CD | 3 | Spring centered, all ports closed at center | Cylinder locked in mid-position | Double-acting cylinders requiring mid-position hold |
How to choose: If your cylinder must hold its position when the valve de-energizes - for example, a clamping fixture on a machining center - choose 2BA (2-position, all ports closed). If your cylinder must return to a defined position on power loss, choose a spring-offset spool (2BD or 2BP). If you need mid-position holding in a 3-position circuit, choose 4CD.
2.2 Pressure and Flow – 35 MPa / 100 L/min in a CETOP 3 Body
The KSO-G02 delivers 35 MPa maximum operating pressure and 100 L/min maximum flow - performance that exceeds most CETOP 3 solenoid valves on the market.
| Parameter | KSO-G02 | Typical CETOP 3 Valve |
|---|---|---|
| Maximum Pressure | 35 MPa (5,076 PSI) | 25–31.5 MPa |
| Maximum Flow | 100 L/min | 60–80 L/min |
| Allowable Back Pressure | 17.5 MPa (175 kgf/cm²) | 10–14 MPa |
| Switching Frequency | 240 cycles/min | 120–180 cycles/min |
What this means for your system design: You can use a smaller manifold block (CETOP 3 instead of CETOP 5) for the same hydraulic power, reducing manifold weight and cost. The high allowable back pressure (17.5 MPa) also means the valve can tolerate return-line pressure spikes without malfunction - critical in systems where multiple actuators share a common return line.
2.3 Voltage Options – Match the Coil to Your Control System
The KSO-G02 is available in a full range of AC and DC coil voltages. The voltage code is the last character group in the model number:
| Voltage Code | Coil Voltage | Holding Power | Best For |
|---|---|---|---|
| A | AC100V (50Hz) / AC100–110V (60Hz) | 22W / 18–23W | Japanese and Asian machine tools |
| B | AC200V (50Hz) / AC200–220V (60Hz) | 22W / 18–23W | Asian and European industrial systems |
| C | AC110V (50Hz) / AC120V (60Hz) | 22W / 23W | North American machine tools |
| D | AC220V (50Hz) / AC240V (60Hz) | 22W / 23W | European and Asian industrial power supplies |
| P | DC24V | 30W | Modern PLC-controlled systems |
| N | DC12V | 29W | Mobile equipment and low-voltage systems |
Coil connection options include terminal box type (standard) and DIN connector type. The terminal box type includes an earth terminal for CE compliance and an integrated surge killer for electrical protection.
2.4 IP65 Protection – Built for Harsh Industrial Environments
The KSO-G02 features a dust-proof and waterproof construction that meets IEC Pub529 IP65 ingress protection standards. This means:
Dust cannot enter the solenoid coil or terminal area
Water spray from any direction will not cause malfunction
Suitable for CE-compliant equipment in European markets
Practical benefit: In machine shops where coolant mist and metal chips are present, or in outdoor hydraulic power units exposed to rain and wash-down, the IP65 rating eliminates the need for additional enclosure protection. The valve can be mounted directly on the manifold without a protective cabinet.
2.5 Cross-Reference Compatibility – Drop-In Replacement for Major Brands
The KSO-G02 is designed to the CETOP 3 / NG6 / NFPA D03 standard mounting interface. This means it will bolt directly onto any manifold machined for this standard. More importantly, the spool functions and port patterns are cross-compatible with major competing brands:
| Competing Brand | Equivalent Series | Notes |
|---|---|---|
| Yuken | DSG-01 series | Spool function codes (2B2, 3C60, etc.) map to KSO codes |
| Nachi | SS-G01 series | Direct interchange for most spool types |
| Parker | D1VW series | CETOP 3 mounting, similar spool logic |
| Tokyo Keiki | DG4V-3 series | Standard CETOP 3 interchange |
| Toyo-Oki | HD3 series | Direct mounting compatibility |
What this means for you: If you are replacing a Yuken DSG-01, a Nachi SS-G01, or a Parker D1VW valve on an existing machine, the KSO-G02 equivalent spool function will bolt directly onto the same manifold and perform the same function. Confirm the spool function code mapping before ordering.
2.6 Low-Wattage Coil Option – Drive Directly from PLC Output
For systems controlled by programmable logic controllers (PLC), the KSO-G02 is available with a low-wattage coil (DC:5W or AC:12W). The low current requirement allows the valve to be driven directly from a programmable sequence controller output without an intermediate relay.
Practical benefit: Fewer components in the control cabinet, simpler wiring, reduced panel space, and one less failure point per valve. For systems with multiple solenoid valves, the cumulative savings in relays and wiring can be significant.





Q1: How do I read the KSO-G02 model code?
The KSO-G02 order code follows this structure:
KSO-G02-[Spool Function]-[Design No.]-[Voltage Code]
| Code Segment | Meaning | Examples |
|---|---|---|
| KSO | Solenoid-operated directional control valve | - |
| G02 | Nominal size: 1/4 (CETOP 3 / NG6) | G02 = 100 L/min; G03 = 160 L/min |
| Spool Function | Flow path and spring configuration | 2BA, 2BD, 2BP, 4CD |
| Design No. | Internal design revision | 10, 30 |
| Voltage Code | Coil voltage | AC220V (D), DC24V (P) |
Example: KSO-G02-2BA-30-AC220V = G02 size, 2-position all-port-closed spool, design 30, AC220V coil.
Q2: What is the difference between 2BA, 2BD, 2BP, and 4CD?
| Spool Code | Positions | Function | Power-Off Behavior |
|---|---|---|---|
| 2BA | 2 | All ports closed | Cylinder locked - oil trapped |
| 2BD | 2 | Spring offset | Cylinder returns to home position |
| 2BP | 2 | Spring offset (opposite direction) | Cylinder returns to home position |
| 4CD | 3 | Spring centered | All ports closed at center - mid-position hold |
How to choose: Clamping application where cylinder must not move on power loss → 2BA. Single-acting cylinder that returns on power loss → 2BD or 2BP. Double-acting cylinder requiring mid-position hold → 4CD.
Q3: What is the maximum pressure and flow for the KSO-G02?
Maximum operating pressure: 35 MPa (350 kgf/cm² / 5,076 PSI).
Maximum flow: 100 L/min.
Allowable back pressure: 17.5 MPa (175 kgf/cm²).
Maximum switching frequency: 240 cycles/min.
Q4: Can I replace a Yuken DSG-01 with a KSO-G02?
Yes, in most cases. Both valves use the CETOP 3 / NG6 / ISO 4401-AB-03 mounting interface, so the KSO-G02 will bolt directly onto a manifold designed for the Yuken DSG-01. The spool function must be matched - for example, Yuken DSG-01-2B2 corresponds to KSO-G02-2BA (both are 2-position, all-port-closed). Confirm the spool function mapping before ordering.
Q5: What is the difference between G02 and G03?
| KSO-G02 | KSO-G03 | |
|---|---|---|
| Nominal diameter | 1/4 (CETOP 3 / NG6) | 3/8 (CETOP 5 / NG10) |
| Maximum flow | 100 L/min | 160 L/min (DC) / 130 L/min (AC) |
| Mounting bolts | M5 | M6 (optional M8) |
| Best for | Flow ≤100 L/min | Flow >100 L/min |
Selection rule: If your system flow requirement is ≤100 L/min, choose G02 - it is more compact and lower cost. If flow exceeds 100 L/min, step up to G03.
Q6: What voltage options are available?
Full range of AC and DC voltages: AC100V, AC110V, AC200V, AC220V, AC240V, DC12V, DC24V. The voltage code (last character group in the model number) determines the coil specification. For AC220V, the code is D; for DC24V, the code is P.
Q7: What is the IP protection rating?
IEC Pub529 IP65 - dust-proof and waterproof. Suitable for machine tool environments with coolant mist, outdoor hydraulic power units, and CE-compliant equipment.
Q8: What hydraulic fluid is compatible?
Petroleum-based hydraulic fluids (mineral oil) . Operating temperature range: 30–90°C. Filtration: maintain fluid cleanliness to the valve manufacturer's specification - typically ISO 4406 code 18/16/13 or better for long service life.
Q9: What is the recommended mounting orientation?
The valve can be mounted in any orientation. However, for 2-position spring-offset spools, mounting with the solenoid horizontal is preferred to avoid gravity-assisted drift during maintenance. For 3-position spring-centered spools (4CD) , orientation has no effect on function.
Q10: Do you provide test reports?
Yes. Each KSO-G02 valve undergoes factory testing before shipment, including solenoid function test, leakage test, and pressure/flow verification. Test data and videos are available upon request.
Products Description
| Item | A2VK12 | A2VK28 | A2VK55 | A2VK107 |
|---|---|---|---|---|
| Max Geometric Displacement | 11.6 cm³/rev | 28.1 cm³/rev | 54.8 cm³/rev | 107 cm³/rev |
| Rated Working Pressure | 250 bar (25 MPa) | 250 bar (25 MPa) | 250 bar (25 MPa) | 250 bar (25 MPa) |
| Peak Pressure | 315 bar (31.5 MPa) | 315 bar (31.5 MPa) | 315 bar (31.5 MPa) | 315 bar (31.5 MPa) |
| Max Speed | 1450 rpm | 1450 rpm | 1450 rpm | 1450 rpm |
| Max Flow @1450rpm | 16.8 L/min | 40.7 L/min | 79.5 L/min | 155.2 L/min |
| Max Power @ Δp=250bar,1450rpm | 6.8 kW | 16.5 kW | 32.1 kW | 62.7 kW |
| Weight | 19 kg | 36 kg | 64 kg | 120 kg |
| Control Type | Handwheel manual variable with precision scale | Handwheel manual variable with precision scale | Handwheel manual variable with precision scale | Handwheel manual variable with precision scale |
| Shaft Seal | Double shaft seal + buffer fluid port (for PU medium) | Double shaft seal + buffer fluid port (for PU medium) | Double shaft seal + buffer fluid port (for PU medium) | Double shaft seal + buffer fluid port (for PU medium) |
| Mount Flange | ISO standard mounting flange | ISO standard mounting flange | ISO standard mounting flange | ISO standard mounting flange |
| Port Type | SAE threaded ports, chemical medium compatible | SAE threaded ports, chemical medium compatible | SAE threaded ports, chemical medium compatible | SAE threaded ports, chemical medium compatible |
| Application Medium | Polyol / Isocyanate (PU raw materials) | Polyol / Isocyanate (PU raw materials) | Polyol / Isocyanate (PU raw materials) | Polyol / Isocyanate (PU raw materials) |
| Recommended Hydraulic Oil (Drive side) | ISO VG32 / VG46 anti-wear mineral HLP oil | ISO VG32 / VG46 anti-wear mineral HLP oil | ISO VG32 / VG46 anti-wear mineral HLP oil | ISO VG32 / VG46 anti-wear mineral HLP oil |
| Operating Temperature | -10 ~ +80 ℃ | -10 ~ +80 ℃ | -10 ~ +80 ℃ | -10 ~ +80 ℃ |
A2VK Series Axial Piston Metering Pump (Polyurethane High Pressure Variable Pump) A2VK series is a high-precision axial piston variable metering pump, specially designed for polyurethane foaming machinery, used for precise proportional delivery of polyol and isocyanate. Equipped with integrated handwheel with precision scale, stepless adjustment of displacement. Double shaft seal structure with buffer fluid port, suitable for chemical medium, low pulsation, high volumetric efficiency, stable metering performance. Widely used in PU high-pressure foaming injection system, chemical proportioning metering system.
A2VK □ □ □ □ □ - S02
- Size:12/28/55/107
- Control: MA = Manual handwheel adjustment
- Rotation: R=Clockwise, L=Counter-clockwise
- Seal / Material: G=Standard seal for PU medium
- Port: P=SAE threaded port
Hot Tags: kso-g02-2ba-30 kso-g02-2bd-10 kso-g02-2bp-30 kso-g02-4cd-30 solenoid valve, China kso-g02-2ba-30 kso-g02-2bd-10 kso-g02-2bp-30 kso-g02-4cd-30 solenoid valve manufacturers, suppliers
You Might Also Like
Send Inquiry