Veljan Excavators VT6ED Fixed Displacement Electric Piston Pump
video

Veljan Excavators VT6ED Fixed Displacement Electric Piston Pump

The Veljan VT6ED, VT6CC, and VT6GCC are high-pressure double vane pumps known for their performance and reliability.
Send Inquiry
Product Introduction

Veljan Excavators VT6ED Fixed Displacement Electric Piston Pump

 

New electric power options for excavator hydraulic systems

 

In the context of energy conservation and emission reduction, excavators are gradually adopting electrified components to reduce reliance on traditional engine-driven hydraulic systems. The Veljan VT6ED Fixed Displacement Electric Piston Pump is engineered to be a "clean power source" for excavator hydraulic systems, converting electrical energy into stable hydraulic pressure through an electric drive mechanism. As a professional electric piston pump, it abandons the traditional mechanical transmission link, reducing energy loss during power conversion and making excavator operations more efficient and environmentally friendly-whether in urban construction with strict emission requirements or indoor engineering scenarios.

The veljan vt6ed pump is tailored to the working characteristics of excavators. Its fixed displacement design ensures a constant flow output under rated conditions, which is very suitable for actions that require stable power, such as the continuous lifting of the excavator's arm or the uniform rotation of the turntable. The vt6ed pump uses high-precision electrical components and hydraulic structures, and the response time between the start of the electric drive and the output of hydraulic pressure is controlled within 0.5 seconds, ensuring that the excavator's actions are not delayed.

Core advantage: Balancing electric efficiency and operational stability

 

The veljan vt6ed pump stands out for its electric piston pump design, which brings two key advantages: high energy efficiency and low noise. Compared with engine-driven pumps, the electric drive system of this pump has an energy conversion efficiency of more than 85%, which can reduce the overall energy consumption of the excavator by 20% during the same working time. At the same time, the absence of mechanical transmission friction and engine vibration makes the operating noise lower than 70dB, which is especially suitable for urban construction projects near residential areas or indoor excavation operations that require quietness.

Another major advantage is the stable output performance of the vt6ed pump. As a fixed displacement pump, it can maintain a constant flow and pressure output when the excavator is performing continuous operations such as trench digging or material handling, avoiding the pressure fluctuations that may occur in variable displacement pumps. The veljan vt6ed pump also uses a dual-seal structure: the electrical part is isolated from the hydraulic part to prevent hydraulic oil from infiltrating the motor, and the hydraulic chamber uses high-temperature resistant seals to ensure stable operation even when the oil temperature reaches 90°C.

 


 

The Veljan VT6ED, VT6CC, and VT6GCC are high-pressure double vane pumps known for their performance and reliability. Here are some key points regarding their maintenance and operation:

 

Inspection and Lubrication: Regularly inspect the vanes and other critical components for wear or damage. Ensure that all moving parts are properly lubricated to reduce friction and extend the service life of the pump 97.

 

Seal and Gasket Condition: Check the condition of seals and gaskets to prevent any fluid leaks. Replace them if they show signs of wear or damage.

Fluid Quality and Change: Monitor the hydraulic fluid for contamination or degradation. Regularly change the fluid as per the manufacturer's recommendations to maintain its quality and prevent system contamination.

 

Operating Temperature: Keep an eye on the operating temperature of the pump. If necessary, implement cooling measures to prevent overheating, which can lead to reduced efficiency and potential damage.

 

Speed Ratings: Be aware of the maximum speed ratings for the pump, which are influenced by specific gravity, viscosity, and suction head. Ensure that the pump operates within the specified speed limits to avoid damage 98.

 

Pressure Monitoring: Monitor the pressure generated by the pump to ensure it is within the recommended range. Excessive pressure can cause damage to the pump and other components in the hydraulic system.

Prime the Pump: Before starting the pump for the first time, make sure it is properly primed at the lowest possible speed and pressure. This helps to eliminate air from the system and ensures smooth operation.

 

Pump Cartridge: The pump cartridge, which includes components like the cam ring, rotor, port plates, and vanes, should be replaced without major disassembly when necessary. This design allows for easy maintenance and part replacement.

Double and Triple Pumps: For double and triple vane pumps in the VT* series, each pump within the housing operates independently, with its own inlet and outlet ports. This allows for versatile applications and configurations.

 

Mobile Version Vane Pumps: If you are using mobile version vane pumps, ensure that the internal design modifications are taken into account, such as the bi-directional cartridge design, which allows for easy rotation change by adjusting the cam ring position 98.

By following these maintenance tips and adhering to the manufacturer's guidelines, you can ensure the efficient and reliable operation of your Veljan high-pressure double vane pumps. Regular maintenance not only prevents costly repairs but also contributes to the overall longevity of the hydraulic system.

 

Product descriptions from the supplier

 

electric piston pump
vt6ed pump
veljan vt6ed pump
4
5
6
7
8
9
 

T6 Series Pump

 

Size

Series

Cartridges 1

C

6

Rotation

   

T6DC T6EC

T6DCC

T6DCC T6EDC
T6DDC

 

T6C

T6CC T67CB

T67DC T67EC

T67DCC T67DCB

T6CC T67DCC T67EDC T67DDC T6H20C
T6H29C

T6CR

Cam

ml/rev.

Cam Code

3

10.8

034-59050

R (CW)

S24-10692

S24-10731

S24-10767

S24-25551

S24-10749

S24-26354

L (CCW)

S24-10693

S24-10732

S24-10768

S24-25561

S24-10750

S24-26353

5

17.2

034-59051

R (CW)

S24-10694

S24-10733

S24-10769

S24-25552

S24-10751

S24-26356

L (CCW)

S24-10695

S24-10734

S24-10770

S24-25562

S24-10752

S24-36355

6

21.3

034-59052

R (CW)

S24-10696

S24-10735

S24-10771

S24-25553

S24-10753

S24-26358

L (CCW)

S24-10697

S24-10736

S24-10772

S24-25563

S24-10754

S24-26357

8

26.4

034-50953

R (CW)

S24-10698

S24-10737

S24-10773

S24-25554

S24-10755

S24-26360

L (CCW)

S24-10699

S24-10738

S24-10774

S24-25564

S24-10756

S24-26359

10

34.1

034-59054

R (CW)

S24-10721

S24-10739

S24-10775

S24-25555

S24-10757

S24-26362

L (CCW)

S24-10722

S24-10740

S24-10776

S24-25565

S24-10758

S24-26361

12

37.1

034-66595

R (CW)

S24-26478

S24-26509

S24-26480

S24-26484

S24-26482

S24-26383

L (CCW)

S24-26479

S24-26510

S24-26481

S24-26485

S24-26483

S24-26382

14

46

034-59206

R (CW)

S24-10723

S24-10741

S24-10777

S24-25556

S24-10759

S24-26364

L (CCW)

S24-10724

S24-10742

S24-10778

S24-25566

S24-10760

S24-26363

17

58.3

034-59207

R (CW)

S24-10725

S24-10743

S24-10779

S24-25557

S24-10761

S24-26366

L (CCW)

S24-10726

S24-10744

S24-10780

S24-25567

S24-10762

S24-26365

20

63.8

034-66607

R (CW)

S24-26859

S24-26853

S24-40234

S24-40352

S24-31023

S24-31885

L (CCW)

S24-26860

S24-26854

S24-40235

S24-40353

S24-40032

S24-50391

22

70.3

034-59208

R (CW)

S24-10727

S24-10745

S24-10781

S24-25558

S24-10763

S24-26368

L (CCW)

S24-10728

S24-10746

S24-10782

S24-25568

S24-10764

S24-26367

25

79.3

034-59209

R (CW)

S24-10729

S24-10747

S24-10783

S24-25559

S24-10765

S24-26370

L (CCW)

S24-10730

S24-10748

S24-10784

S24-25569

S24-10766

S24-26369

28

88.8

034-59245

R (CW)

S14-97761

S24-25510

S14-97722

S24-25560

S24-25547

S24-26372

L (CCW)

S24-25519

S14-97738

S24-25791

S24-25570

S24-25546

S24-26371

31

100

034-66843

R (CW)

S24-45785

S24-45787

S24-45789

S24-45773

S24-45771

S24-49442

L (CCW)

S24-45786

S24-45788

S24-45790

S24-45774

S24-45772

S24-49443

Port-Plates

Pressure

R (CW)

034-59772

034-59772

034-59773

034-66521

034-59773

034-59772

L (CCW)

034-59773

034-59773

034-59772

034-66522

034-59772

034-59773

Rear ass'y 3

R (CW)

S24-10803

S24-10805

S24-10809

S24-10806

S24-10807

S24-10808

L (CCW)

S24-10804

S24-10806

S24-10810

S24-10805

S24-10808

S24-10807

 

 

original performance

 

There are many advantages in these products:high flow, high pressure, low noise, long life, high volumetric efficiency and so on.

 

High-reliability and wide range application

 

T6 series vane pumps have complete varieties and specifications, high-quality performance, simple and reasonable structure, easy installation and maintenance (the installation is compliant with ISO / SAE standard)

 

Wide-range in application

 

T6 pump can be widely used in machine tools,pressure die casting machinery, engineering machinery, metallurgy, mining, light industry, chemical industry machinery,agricultural machinery, as well as various types of hydraulic systems and other fields.

Hot Tags: veljan excavators vt6ed fixed displacement electric piston pump, China veljan excavators vt6ed fixed displacement electric piston pump manufacturers, suppliers, axial displacement pump, cat 190 2279, cat 202 1335 pump, denison t7bb pump, parker variable piston pump, t67dcbs pump

Send Inquiry

whatsapp

Phone

E-mail

Inquiry