Veljan Excavators VT6ED Fixed Displacement Electric Piston Pump
Veljan Excavators VT6ED Fixed Displacement Electric Piston Pump
New electric power options for excavator hydraulic systems
In the context of energy conservation and emission reduction, excavators are gradually adopting electrified components to reduce reliance on traditional engine-driven hydraulic systems. The Veljan VT6ED Fixed Displacement Electric Piston Pump is engineered to be a "clean power source" for excavator hydraulic systems, converting electrical energy into stable hydraulic pressure through an electric drive mechanism. As a professional electric piston pump, it abandons the traditional mechanical transmission link, reducing energy loss during power conversion and making excavator operations more efficient and environmentally friendly-whether in urban construction with strict emission requirements or indoor engineering scenarios.
The veljan vt6ed pump is tailored to the working characteristics of excavators. Its fixed displacement design ensures a constant flow output under rated conditions, which is very suitable for actions that require stable power, such as the continuous lifting of the excavator's arm or the uniform rotation of the turntable. The vt6ed pump uses high-precision electrical components and hydraulic structures, and the response time between the start of the electric drive and the output of hydraulic pressure is controlled within 0.5 seconds, ensuring that the excavator's actions are not delayed.
Core advantage: Balancing electric efficiency and operational stability
The veljan vt6ed pump stands out for its electric piston pump design, which brings two key advantages: high energy efficiency and low noise. Compared with engine-driven pumps, the electric drive system of this pump has an energy conversion efficiency of more than 85%, which can reduce the overall energy consumption of the excavator by 20% during the same working time. At the same time, the absence of mechanical transmission friction and engine vibration makes the operating noise lower than 70dB, which is especially suitable for urban construction projects near residential areas or indoor excavation operations that require quietness.
Another major advantage is the stable output performance of the vt6ed pump. As a fixed displacement pump, it can maintain a constant flow and pressure output when the excavator is performing continuous operations such as trench digging or material handling, avoiding the pressure fluctuations that may occur in variable displacement pumps. The veljan vt6ed pump also uses a dual-seal structure: the electrical part is isolated from the hydraulic part to prevent hydraulic oil from infiltrating the motor, and the hydraulic chamber uses high-temperature resistant seals to ensure stable operation even when the oil temperature reaches 90°C.
The Veljan VT6ED, VT6CC, and VT6GCC are high-pressure double vane pumps known for their performance and reliability. Here are some key points regarding their maintenance and operation:
Inspection and Lubrication: Regularly inspect the vanes and other critical components for wear or damage. Ensure that all moving parts are properly lubricated to reduce friction and extend the service life of the pump 97.
Seal and Gasket Condition: Check the condition of seals and gaskets to prevent any fluid leaks. Replace them if they show signs of wear or damage.
Fluid Quality and Change: Monitor the hydraulic fluid for contamination or degradation. Regularly change the fluid as per the manufacturer's recommendations to maintain its quality and prevent system contamination.
Operating Temperature: Keep an eye on the operating temperature of the pump. If necessary, implement cooling measures to prevent overheating, which can lead to reduced efficiency and potential damage.
Speed Ratings: Be aware of the maximum speed ratings for the pump, which are influenced by specific gravity, viscosity, and suction head. Ensure that the pump operates within the specified speed limits to avoid damage 98.
Pressure Monitoring: Monitor the pressure generated by the pump to ensure it is within the recommended range. Excessive pressure can cause damage to the pump and other components in the hydraulic system.
Prime the Pump: Before starting the pump for the first time, make sure it is properly primed at the lowest possible speed and pressure. This helps to eliminate air from the system and ensures smooth operation.
Pump Cartridge: The pump cartridge, which includes components like the cam ring, rotor, port plates, and vanes, should be replaced without major disassembly when necessary. This design allows for easy maintenance and part replacement.
Double and Triple Pumps: For double and triple vane pumps in the VT* series, each pump within the housing operates independently, with its own inlet and outlet ports. This allows for versatile applications and configurations.
Mobile Version Vane Pumps: If you are using mobile version vane pumps, ensure that the internal design modifications are taken into account, such as the bi-directional cartridge design, which allows for easy rotation change by adjusting the cam ring position 98.
By following these maintenance tips and adhering to the manufacturer's guidelines, you can ensure the efficient and reliable operation of your Veljan high-pressure double vane pumps. Regular maintenance not only prevents costly repairs but also contributes to the overall longevity of the hydraulic system.
Product descriptions from the supplier









T6 Series Pump
|
Size |
Series |
Cartridges 1 |
|||||||
|
C |
6 |
Rotation |
T6DC T6EC |
T6DCC |
T6DCC T6EDC |
||||
|
T6C |
T6CC T67CB |
T67DC T67EC |
T67DCC T67DCB |
T6CC T67DCC T67EDC T67DDC T6H20C |
T6CR |
||||
|
Cam |
ml/rev. |
Cam Code |
|||||||
|
3 |
10.8 |
034-59050 |
R (CW) |
S24-10692 |
S24-10731 |
S24-10767 |
S24-25551 |
S24-10749 |
S24-26354 |
|
L (CCW) |
S24-10693 |
S24-10732 |
S24-10768 |
S24-25561 |
S24-10750 |
S24-26353 |
|||
|
5 |
17.2 |
034-59051 |
R (CW) |
S24-10694 |
S24-10733 |
S24-10769 |
S24-25552 |
S24-10751 |
S24-26356 |
|
L (CCW) |
S24-10695 |
S24-10734 |
S24-10770 |
S24-25562 |
S24-10752 |
S24-36355 |
|||
|
6 |
21.3 |
034-59052 |
R (CW) |
S24-10696 |
S24-10735 |
S24-10771 |
S24-25553 |
S24-10753 |
S24-26358 |
|
L (CCW) |
S24-10697 |
S24-10736 |
S24-10772 |
S24-25563 |
S24-10754 |
S24-26357 |
|||
|
8 |
26.4 |
034-50953 |
R (CW) |
S24-10698 |
S24-10737 |
S24-10773 |
S24-25554 |
S24-10755 |
S24-26360 |
|
L (CCW) |
S24-10699 |
S24-10738 |
S24-10774 |
S24-25564 |
S24-10756 |
S24-26359 |
|||
|
10 |
34.1 |
034-59054 |
R (CW) |
S24-10721 |
S24-10739 |
S24-10775 |
S24-25555 |
S24-10757 |
S24-26362 |
|
L (CCW) |
S24-10722 |
S24-10740 |
S24-10776 |
S24-25565 |
S24-10758 |
S24-26361 |
|||
|
12 |
37.1 |
034-66595 |
R (CW) |
S24-26478 |
S24-26509 |
S24-26480 |
S24-26484 |
S24-26482 |
S24-26383 |
|
L (CCW) |
S24-26479 |
S24-26510 |
S24-26481 |
S24-26485 |
S24-26483 |
S24-26382 |
|||
|
14 |
46 |
034-59206 |
R (CW) |
S24-10723 |
S24-10741 |
S24-10777 |
S24-25556 |
S24-10759 |
S24-26364 |
|
L (CCW) |
S24-10724 |
S24-10742 |
S24-10778 |
S24-25566 |
S24-10760 |
S24-26363 |
|||
|
17 |
58.3 |
034-59207 |
R (CW) |
S24-10725 |
S24-10743 |
S24-10779 |
S24-25557 |
S24-10761 |
S24-26366 |
|
L (CCW) |
S24-10726 |
S24-10744 |
S24-10780 |
S24-25567 |
S24-10762 |
S24-26365 |
|||
|
20 |
63.8 |
034-66607 |
R (CW) |
S24-26859 |
S24-26853 |
S24-40234 |
S24-40352 |
S24-31023 |
S24-31885 |
|
L (CCW) |
S24-26860 |
S24-26854 |
S24-40235 |
S24-40353 |
S24-40032 |
S24-50391 |
|||
|
22 |
70.3 |
034-59208 |
R (CW) |
S24-10727 |
S24-10745 |
S24-10781 |
S24-25558 |
S24-10763 |
S24-26368 |
|
L (CCW) |
S24-10728 |
S24-10746 |
S24-10782 |
S24-25568 |
S24-10764 |
S24-26367 |
|||
|
25 |
79.3 |
034-59209 |
R (CW) |
S24-10729 |
S24-10747 |
S24-10783 |
S24-25559 |
S24-10765 |
S24-26370 |
|
L (CCW) |
S24-10730 |
S24-10748 |
S24-10784 |
S24-25569 |
S24-10766 |
S24-26369 |
|||
|
28 |
88.8 |
034-59245 |
R (CW) |
S14-97761 |
S24-25510 |
S14-97722 |
S24-25560 |
S24-25547 |
S24-26372 |
|
L (CCW) |
S24-25519 |
S14-97738 |
S24-25791 |
S24-25570 |
S24-25546 |
S24-26371 |
|||
|
31 |
100 |
034-66843 |
R (CW) |
S24-45785 |
S24-45787 |
S24-45789 |
S24-45773 |
S24-45771 |
S24-49442 |
|
L (CCW) |
S24-45786 |
S24-45788 |
S24-45790 |
S24-45774 |
S24-45772 |
S24-49443 |
|||
|
Port-Plates |
Pressure |
R (CW) |
034-59772 |
034-59772 |
034-59773 |
034-66521 |
034-59773 |
034-59772 |
|
|
L (CCW) |
034-59773 |
034-59773 |
034-59772 |
034-66522 |
034-59772 |
034-59773 |
|||
|
Rear ass'y 3 |
R (CW) |
S24-10803 |
S24-10805 |
S24-10809 |
S24-10806 |
S24-10807 |
S24-10808 |
||
|
L (CCW) |
S24-10804 |
S24-10806 |
S24-10810 |
S24-10805 |
S24-10808 |
S24-10807
|
|||
original performance
There are many advantages in these products:high flow, high pressure, low noise, long life, high volumetric efficiency and so on.
High-reliability and wide range application
T6 series vane pumps have complete varieties and specifications, high-quality performance, simple and reasonable structure, easy installation and maintenance (the installation is compliant with ISO / SAE standard)
Wide-range in application
T6 pump can be widely used in machine tools,pressure die casting machinery, engineering machinery, metallurgy, mining, light industry, chemical industry machinery,agricultural machinery, as well as various types of hydraulic systems and other fields.
Hot Tags: veljan excavators vt6ed fixed displacement electric piston pump, China veljan excavators vt6ed fixed displacement electric piston pump manufacturers, suppliers, axial displacement pump, cat 190 2279, cat 202 1335 pump, denison t7bb pump, parker variable piston pump, t67dcbs pump
You Might Also Like