系列号 Series | 类别型号 Type code | 类别型号 Type code | 排量代号 Flow code | 轴伸形式 Shaft type | 族转方向 Rotation | 设计号 Design number | 密封等级 Sealing level | 油口尺寸 Port dimensions |
M4C M4C1 M4SC M4SC1 | 无:外泄 No: External 1:内泄 1: Internal | 无:标准 No: standard S:重载 S: heavy load | 024、027、 031.043. 055、067 075 | 见轴伸尺寸 See size of the shaft | 双向 (注:顺时针 =进油口A, 逆时针=进油 口B) Bi-directional (Note:cloc- kwise=inlet A.counter- clockwise= inlet B) | A | M4: 1-丁睛橡胶 5-氟橡胶 M4: 1-NBR Nitrile rubber M4S: 5-氟橡胶 M4S: | 01、02、04、M4 见安装连接尺寸 See installation dimensions |
M4D M4D1 M4SD M4SD1 | 062、074. 088、102、 113. 128. 138 | |||||||
M4E M4E1 M4SE M4SE1 | 153、185、 214、 | 01、02、 04 见安装连接尺寸 See installation dimensions |
型号 Model | 轴伸代号 Shaft code | 轴伸形式 Shaft type | L1 | L2 | DIA | K1xK2 | H1 |
M4C | 1 | 平键Keyed:SAE-B(●22.2) | 71.4 | 38.1 | 22.225-22.200 | 6.35×6.30 | 29.94 |
2 | 平键Keyed:非NonSAE(●22.2) | 58.7 | 31.7 | 22.225-22.200 | 4.77×4.72 | 24.5 | |
3 | 花键Splined:SAE-B | 41.4 | 24.5 | SAEJ498b1级,径节16/32,13牙 SAE J498b class 1,Diametral pitch 16/32,13T | |||
M4D | 1 | 平建Keyed:SAE-C(φ31.7) | 55.6 | 38.1 | 31.750-31.700 | 7.94×7.89 | 35.28 |
3 | 花键Splined:SAE-C | 55.6 | 38.1 | SAEJ498b1级,径节12/24,14牙, SAE J498b class 1,Diametral pitch 12/24,14T | |||
M4E | 1 | 平键Keyed:SAE-C(φ31.7) | 84.1 | 49.3 | 31.750-31.700 | 7.94×7.89 | 35.29 |
3 | 花键Splined:SAE-C | 55.7 | 25.2 | SAEJ498b1级,径节12/24,14牙 SAE J498b class 1,Diametral pitch 12/24,14T |
油口/Oil port | 安装尺寸/Install Dimension(mm) | |||||
A&B | 泄油口Drain port D | |||||
SAE4孔法兰(油口代号:02,04,M4) SAE 4 Hole flange (Oil port code: 02, 04, M4) | SAE螺纹油口(代号:01) SAEThreaded port (Code: 01) | |||||
A1 | B1 | C1 | T1口螺纹Thread | |||
M4C/M4SC | 52.4 | 26.2 | 25.4 | SAE: 8/3 16 UNC×19.0 公制Metric:M10×20.0 | 1 5/16 UNF×19.0 | SAE: 7/16 20UyF BSPP: 1/4 |
M4D/M4SD | 58.7 | 30.2 | 31.8 | SAE: 7/6 14UNC×22.0 公制Metric: M12×222.1 | 1 5/8 UNF ×19.0 | SAE: 3/4 16UNF BSPP:3/8 |
M4E/M4SE | 77.8 | 42.9 | 50 | 1/2 13UNC×26.9 | 2 1/2 12UNF×19.0 | SAE:3/4 16UNF BSPp:1/2 |
To protect your rights please read the following carefully Pump Start-up Procedure Preparation Prior to Start-up The reservoir and circuit should be clean and free of dirt and debris prior to filling with fluid. Circuit Cleanup The reservoir should be charged with filtered hydraulic fluid. The fluid level should be sufficient to prevent vortexing at the suction connection to the pump inlet. It is good practice to clean the system by flushing and filtering, using an external slave pump. Filling Pump and Removing Air If the pump is mounted above the fluid level, it should be filled with fluid through the outlet port. If the pump is mounted below the fluid level, the pump outlet fitting (or other downstream fitting or plug) can be loosened to allow fluid to displace the air. It may be necessary to loosen the fill cap on the reservoir to allow the fluid to flow freely. When a solid stream of fluid with no observed air begins to drain through the loosened fitting, the fitting should be retightened. An air bleed valve in the outlet circuit is also recommended to remove trapped air. If such a device is used, the pump should be filled with fluid before start-up. In some cases, it may be possible to prime the pump by running the engine starter for five to ten seconds with the throttle and/or ignition switch in the "off" position. It will be necessary to loosen a fitting or plug in the pump outlet to allow air to escape. Pump Start-up All controls should be placed in the neutral position so the pump is unloaded when started. Start the engine and run at low idle. Once the pump is started, it should prime and pump within a few seconds. If it does not, make sure there are no restrictions between the reservoir and the inlet to the pump, and that there are no air leaks in the inlet line and connections. Also, make sure that trapped air can escape from the outlet. Run at low engine idle for approximately five minutes. Then, while observing the reservoir fluid level, operate the implements. Extend all actuators to maximum safe limits to completely fill the system with fluid. Do not run with the fluid level below the "low" limit. Add fluid to the reservoir to bring the fluid to the proper fill level.