Overview of PVM for Wegener plunger pumps:
The working noise of PVM series plunger pumps is very low, and the level of quietness once exceeded the requirements for industrial conditions today. The characteristics of the PVM series of Weigesi plunger pumps are a unique 3-piece structure (flange, housing, and valve block) designed specifically to reduce fluid and structural noise. Another feature of the pump - the bimetallic flow plate - improves the pump's filling characteristics, reduces fluid noise, and extends the pump's lifespan.
123AL00370A PVM098ER10GS02AAA28000000A0A
123AL00889A PVM098ER10GS02AAE0020000EA0A
2-335172 PVM131ER10GS02AAA28000000A0A
123AL01587A PVM063ER09GS02AAC23110000A0A
02-334321 PVM045ER05CS02AAA28000000A0A
Vicker PVM018 Variable piston pump control options:
Pressure compensator control - code A
Under pre adjusted compensator pressure, the pump will provide continuously adjusted flow to meet changing load requirements. If the pressure is lower than the set value of the compensator, the pump will operate at a high displacement.
Warning: The pressure compensator may be adjusted beyond the rated pressure of the pump. When adjusting the pressure limiter, install a 0-350bar (0-5000) pressure gauge on the outlet pressure gauge to limit the pressure setting to the continuous rated pressure corresponding to the pump displacement;
123AL01346A PVM045ER06CS04AAA28000000A0A
123AL00457A PVM045ER05CE0200A23000000A0A
123AL00536A PVM081ER09ES02AAA23000000A0A
123AL00561A PVM074ER09GS02AAE0020000AA0A
123AL00565A PVM098ER10GS02AAA2800000EA0A
Vicker PVM018 Variable displacement Plunger Pump Load Sensing and Pressure Compensator Control
-Code B or C
The pump will provide pump output power that matches the system load requirements, enabling any directional control valve installed between the pump and load to achieve high efficiency and improve load throttling characteristics.
The load sensing ensures that the pump always only provides the flow required by the load, and the working pressure of the pump is adjusted to the actual load pressure plus the pressure difference required by the control action. When the system does not require power, the load sensing control will be in energy-saving standby mode.
Usually, the pressure difference is between the pressure inlet and the working port of the proportional directional valve (or load sensing directional valve).
123AL00576A PVM131ER10GS02AAB2320000EA0A
123AL00652A PVM063ER09EE01AAA07000000A0A
123AL00669A PVM045ER05CE01AAB28110000A0A
123AL00670A PVM074ER10ES02AAB28110000A0A
123AL00671A PVM098ER10GS02AAB28110000A0A
123AL00689A PVM131ER10GS04AAA28000000A0A
123AL00690A PVM098ER09GS04AAA28000000A0A
123AL00696A PVM074ER09GS04AAC28200000A0A
Vicker PVM018 Variable displacement Plunger Pump Load Sensing and Pressure Compensator Control
-Code B or C
The pump will provide pump output power that matches the system load requirements, enabling any directional control valve installed between the pump and load to achieve high efficiency and improve load throttling characteristics.
The load sensing ensures that the pump always only provides the flow required by the load, and the working pressure of the pump is adjusted to the actual load pressure plus the pressure difference required by the control action. When the system does not require power, the load sensing control will be in energy-saving standby mode.
Usually, the pressure difference is between the pressure inlet and the working port of the proportional directional valve (or load sensing directional valve).
123AL00697A PVM098ER09GS04AAC28200000A0A
123AL00699A PVM045ER06CS05AAC28200000A0A
123AL00700A PVM018ER02AS05AAC28200000A0A
123AL00724A PVM074ER09ES02AAC23200000A0A
123AL00739A PVM018ER05CS02AAC28110000A0A
123AL00740A PVM057ER09GS02AAC28200000A0A
123AL00741A PVM074ER09GS02AAC28200000A0A
123AL00742A PVM098ER09GS02AAC28200000A0A
If the load pressure exceeds the system pressure setting, the pressure compensator reduces the pump displacement. The load sensing pipeline must be as short as possible and can also be used for remote control or unloading of pump pressure.
Warning: The pressure compensator may be adjusted beyond the rated pressure of the pump. When adjusting the pressure limiter, install a 0-350 bar (0-5000) pressure gauge on the outlet pressure gauge to limit the pressure setting to the continuous rated pressure for the pump displacement.
123AL00744A PVM141ER10GS02AAC23200000A0A
123AL00749A PVM045ER05CS0200C2320000CA0A
123AL00756A PVM074ER09GS02AAC28110000A0A
123AL00757A PVM098ER09GS02AAC28110000A0A
123AL00768A PVM141ER13GS02AAE00200000A0A
123AL00775A PVM045ER05CE05AAA07000000A0A
123AL00783A PVM074ER19FS04AAA28000000A0A
123AL00793A PVM131ER13GS02AAA28000000A0A
123AL00823A PVM018ER03AE01AAB28200000A0A
123AL00848A PVM045ER06CS02AAC2320000AA0A
123AL00872A PVM045ER06CS02AAC2811000DA0A
We Can Provide These Model Pump Inner Parts & Complete Unit For Excavator